Measurements of PM1, PM2.5 and PM10 in air at Nordic background stations using low-cost equipment
IVL Svenska Miljöinstitutet.
Visa övriga samt affilieringar
2008 (Engelska)Rapport (Övrigt vetenskapligt)
Abstract [sv]

Mass concentrations of PM1, PM2.5 and PM10 in air were measured at four EMEP stations in the Nordic countries during 2006. All stations used the same low-cost equipment for sampling PM1, but used different techniques for the other size fractions. The PM1 filters were analysed for inorganic ions for the first half of June. PM1 constituted on average more than half of the PM2.5 concentrations, but was on average less than half of the PM10 concentrations. There were two episodes of high PM1 concentrations during the year, one in May-June and another one in August-September. The highest PM1 concentrations were found during South-Easterly wind trajectories and lowest concentrations during northerly trajectories. Even though the annual average mass relations between the three size fractions were rather independent of the trajectory sectors, the fine and the coarse particle masses were not correlated on a daily basis. The PM2.5 concentration, which is the parameter that should be measured within EU, correlated fairly well with the concentration of accumulation mode particles (PM1). In June only a minor fraction of PM1 consisted of inorganic ions. Only ammonium and sulphate ions of the measured ions in PM1 were well correlated with one another.

Abstract [en]

Mass concentrations of PM1, PM2.5 and PM10 in air were measured at four EMEP stations in the Nordic countries during 2006. All stations used the same low-cost equipment for sampling PM1, but used different techniques for the other size fractions. The PM1 filters were analysed for inorganic ions for the first half of June. PM1 constituted on average more than half of the PM2.5 concentrations, but was on average less than half of the PM10 concentrations. There were two episodes of high PM1 concentrations during the year, one in May-June and another one in August-September. The highest PM1 concentrations were found during South-Easterly wind trajectories and lowest concentrations during northerly trajectories. Even though the annual average mass relations between the three size fractions were rather independent of the trajectory sectors, the fine and the coarse particle masses were not correlated on a daily basis. The PM2.5 concentration, which is the parameter that should be measured within EU, correlated fairly well with the concentration of accumulation mode particles (PM1). In June only a minor fraction of PM1 consisted of inorganic ions. Only ammonium and sulphate ions of the measured ions in PM1 were well correlated with one another.

Ort, förlag, år, upplaga, sidor
IVL Svenska Miljöinstitutet, 2008.
Serie
B-rapport ; B1791
Nyckelord [sv]
EMEP stations, PM1, PM2.5, PM10, trajectories, inorganic ions
Identifikatorer
URN: urn:nbn:se:ivl:diva-2376OAI: oai:DiVA.org:ivl-2376DiVA, id: diva2:1551819
Tillgänglig från: 2021-05-05 Skapad: 2021-05-05 Senast uppdaterad: 2021-05-05Bibliografiskt granskad

Open Access i DiVA

fulltext(365 kB)105 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 365 kBChecksumma SHA-512
bb02f506f7377bbc544d2162ac85fb5da7ac5dcbae6cee6e2404f3500c19ec8fd0fa64ea5d77888034ae505e8f3e8ba73a7bc73c02355874d28dc24fac7e5abe
Typ fulltextMimetyp application/pdf

Sök vidare i DiVA

Av författaren/redaktören
Ferm, Martin
Av organisationen
IVL Svenska Miljöinstitutet

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 110 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 143 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf