IVL Swedish Environmental Research Institute

ivl.se
Change search
Refine search result
1 - 30 of 30
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1. Bekö, G.
    et al.
    Wargocki, P.
    Wang, N.
    Li, M.
    Weschler, C.J.
    Morrison, G.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Emle, L.
    Licina, D.
    Yang, S.
    Zannoni, N.
    Williams, J.
    The Indoor Chemical Human Emissions and Reactivity project (ICHEAR): Overview of experimental methodology and preliminary results.2020In: Indoor Air, ISSN 0905-6947, E-ISSN 1600-0668, Vol. 30, p. 1213–1228-Article in journal (Refereed)
    Abstract [en]

    With the gradual reduction of emissions from building products, emissions from human occupants become more dominant indoors. The impact of human emissions on indoor air quality is inadequately understood. The aim of the Indoor Chemical Human Emissions and Reactivity (ICHEAR) project was to examine the impact on indoor air chemistry of whole-body, exhaled, and dermally emitted human bioeffluents under different conditions comprising human factors (t-shirts/shorts vs long-sleeve shirts/pants; age: teenagers, young adults, and seniors) and a variety of environmental factors (moderate vs high air temperature; low vs high relative humidity; presence vs absence of ozone). A series of human subject experiments were performed in a well-controlled stainless steel climate chamber. State-of-the-art measurement technologies were used to quantify the volatile organic compounds emitted by humans and their total OH reactivity; ammonia, nanoparticle, fluorescent biological aerosol particle (FBAP), and microbial emissions; and skin surface chemistry. This paper presents the design of the project, its methodologies, and preliminary results, comparing identical measurements performed with five groups, each composed of 4 volunteers (2 males and 2 females). The volunteers wore identical laundered new clothes and were asked to use the same set of fragrance-free personal care products. They occupied the ozone-free (<2 ppb) chamber for 3 hours (morning) and then left for a 10-min lunch break. Ozone (target concentration in occupied chamber ~35 ppb) was introduced 10 minutes after the volunteers returned to the chamber, and the measurements continued for another 2.5 hours. Under a given ozone condition, relatively small differences were observed in the steady-state concentrations of geranyl acetone, 6MHO, and 4OPA between the five groups. Larger variability was observed for acetone and isoprene. The absence or presence of ozone significantly influenced the steady-state concentrations of acetone, geranyl acetone, 6MHO, and 4OPA. Results of replicate experiments demonstrate the robustness of the experiments.

  • 2.
    Bloom, Erica
    et al.
    IVL Swedish Environmental Research Institute.
    Sandö, Peter
    Erlandsson, Martin
    IVL Swedish Environmental Research Institute.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    MIOC - Mögel och påväxt i relation till inneklimat och byggnadsegenskaper2013Report (Other academic)
    Abstract [sv]

    Projektets bas är en inventering av 24 kyrkor som ett representativt urval från 12 av Sveriges 13 stift. Inventeringen omfattar; luftkvalitetsmätningar, inventering av mögelförekomst, samt beskrivning av mikroklimatnischer, byggteknik och användning (brukarmönster). Resultatet av inventeringen utgör en egenskapsprofil per kyrka som sedan sätts i relation till uppmätta data för relativ fuktighet och temperatur i kyrkorna. Inget samband har identifierats mellan förekomst av mikrobiella skador och de aspekter som finns i egenskapsprofilen. Däremot har en hypotes ställts upp som utgår ifrån att från litteraturen etablerade kritiska fukttillstånd för trä bör kunna användas som ett styrande kriterium för att undvika mikrobiella skador i kyrkorna. Dessa kritiska fukttillstånd ges för olika relativ fuktighet och varaktighet, det vill säga max; 82procent RF i tre månader, 95 procent RF i fyra veckor och 98 procent RF i ett dygn. Utvärderingen visar att för fem kyrkor där mikrobiell påväxt inte identifierats så ligger parametrarna för kritiskt fukttillstånd under de värden som anges för trä. Beskrivning av kritiska fukttillstånd som tar hänsyn till de tre parametrarna varaktighet, relativ luftfuktighet och temperaturkan därför vara ett bättre sätt och bör kunna ersätta äldre kriterier för styr och regler som ofta bara anger en kritisk nivå för relativ luftfuktighet. Fortsatt arbete bör inriktas på att validera detta samband genom analys av fler kyrkor utan mikrobiella skador samtidigt som de kritiska fukttillstånden analyseras. Det samband som identifierats kan tillämpas för att optimera strategierna för styrningen av inneklimatet i kyrkor så att såväl energianvändningen som risken för skador relaterade till mögel och mikrobiell påväxt minimeras.

    Download full text (pdf)
    FULLTEXT01
  • 3. Cabovská, Blanka
    et al.
    Bekö, Gabriel
    Teli, Despoina
    Ekberg, Lars
    Dalenbäck, Jan-Olof
    Wargocki, Pawel
    Psomas, Theofanis
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Ventilation strategies and indoor air quality in Swedish primary school classrooms2022In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 226, p. 109744-109744, article id 109744Article in journal (Refereed)
    Abstract [en]

    The present study aimed at investigating the effects of ventilation strategies on indoor air quality (IAQ) in schools. Measurements of thermal environment and IAQ were performed over 5 school days in 45 primary school classrooms in Gothenburg, Sweden, grouped into three categories according to their ventilation system: category A) natural or exhaust ventilation, or automated window opening; category B) balanced mechanical ventilationsystems with constant air volume (CAV) and category C) balanced mechanical ventilation systems with variable air volume (VAV). The classrooms performed equally well with respect to temperature and relative humidity regardless of the ventilation system. The concentrations of the air pollutants in all classrooms were generally below the respective guideline values. The concentrations of CO2, formaldehyde, PM10, and PM2.5 were lower in the B and C category classrooms with higher ventilation rates than in the A category classrooms. Indoor Air Pollution Index integrating concentrations of multiple pollutants was significantly higher the A category classrooms, reflecting poorer IAQ. Majority of the classrooms had lower ventilation rates than the Swedish ventilation requirements. The periodically reduced ventilation rates in the classrooms with VAV systems did not lead to substantial increase in the measured indoor pollutant concentrations.

  • 4.
    Giovanoulis, Georgios
    et al.
    IVL Swedish Environmental Research Institute.
    Anh Nguyen, Minh
    IVL Swedish Environmental Research Institute.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Vestergren, Robin
    IVL Swedish Environmental Research Institute.
    Arwidsson, Maria
    Lagerqvist, Anne
    Reduction of hazardous chemicals in Swedish preschool dust through article substitution actions2019In: Environment International, ISSN 0160-4120, E-ISSN 1873-6750Article in journal (Refereed)
  • 5.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Chemical cycling and deposition of atmospheric mercury in polar regions: review of recent measurements and comparison with models.2016In: Atmospheric Chemistry And Physics, ISSN 1680-7316, E-ISSN 1680-7324, Vol. 16, p. 10735–10763-Article in journal (Refereed)
    Abstract [en]

    Mercury (Hg) is a worldwide contaminant that can cause adverse health effects to wildlife and humans. While atmospheric modeling traces the link from emissions to deposition of Hg onto environmental surfaces, large uncertainties arise from our incomplete understanding of atmospheric processes (oxidation pathways, deposition, and re-emission). Atmospheric Hg reactivity is exacerbated in high latitudes and there is still much to be learned from polar regions in terms of atmospheric processes.

    This paper provides a synthesis of the atmospheric Hg monitoring data available in recent years (2011–2015) in the Arctic and in Antarctica along with a comparison of these observations with numerical simulations using four cutting-edge global models. The cycle of atmospheric Hg in the Arctic and in Antarctica presents both similarities and differences. Coastal sites in the two regions are both influenced by springtime atmospheric Hg depletion events and by summertime snowpack re-emission and oceanic evasion of Hg.

    The cycle of atmospheric Hg differs between the two regions primarily because of their different geography. While Arctic sites are significantly influenced by northern hemispheric Hg emissions especially in winter, coastal Antarctic sites are significantly influenced by the reactivity observed on the East Antarctic ice sheet due to katabatic winds. Based on the comparison of multi-model simulations with observations, this paper discusses whether the processes that affect atmospheric Hg seasonality and interannual variability are appropriately represented in the models and identifies research gaps in our understanding of the atmospheric Hg cycling in high latitudes.

  • 6.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Effect of energy renovation on indoor air quality in multifamily residential buildings in Slovakia2017In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 122, p. 363-372Article in journal (Refereed)
    Abstract [en]

    Buildings are responsible for a substantial portion of the global energy consumption. Most of the multifamily residential buildings built in the 20th century in Central and Eastern Europe do not satisfy the current requirements on energy efficiency. Nationwide measures taken to improve the energy efficiency of these buildings rarely consider their impact on the indoor air quality (IAQ). The objective of the present study was to evaluate the impact of simple energy renovation on IAQ, air exchange rates (AER) and occupant satisfaction in Slovak residential buildings.

    Three pairs of identical naturally ventilated multifamily residential buildings were examined. One building in each pair was newly renovated, the other was in its original condition. Temperature, relative humidity (RH) and the concentration of carbon dioxide (CO2) were measured in 94 apartments (57%) during one week in the winter. A questionnaire related to perceived air quality, sick building syndrome symptoms and airing habits was filled by the occupants.

    In a companion experiment, the IAQ was investigated in 20 apartments (50%) of a single residential building before and after its renovation. In this experiment, concentrations of nitrogen dioxide (NO2), formaldehyde and total and individual volatile organic compounds (VOC) were also measured. CO2 concentrations were significantly higher and AERs were lower in the renovated buildings. Formaldehyde concentrations increased after renovation and were positively correlated with CO2 and RH. Energy renovation was associated with lower occupant satisfaction with IAQ. Energy retrofitting efforts should be complemented with improved ventilation in order to avoid adverse effects on IAQ.

  • 7.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Inomhusluftens kvalitet i svenska bostäder – utvärdering av data från undersökningen BETSI2014Report (Other academic)
    Abstract [en]

    This report is only available in Swedish.

    Download full text (pdf)
    FULLTEXT01
  • 8.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Kemikaliesmarta åtgärder i förskola: Kemikaliebelastning i förskolans innemiljö – Hamngården etapp 12016Report (Other academic)
    Abstract [en]

    tockholms stad arbetar proaktivt genom Miljöförvaltningens Kemikaliecentrum med målet ”Giftfritt Stockholm 2030 – kemikaliearbete i världsklass” med speciellt syfte att skydda barn från farliga kemikalier. Som en del i detta genomför Stockholms stad hälsorelaterad miljögiftsövervakning i syfte att undersöka förekomsten av hälsofarliga ämnen i stadens förskolor.

    I denna rapport redovisas resultat från den första etappen av en pilotstudie om kemikaliesmarta åtgärder i en förskola där kemikaliebelastningen i förskolans innemiljö kartläggs och bedöms före och efter ombyggnad där kemikaliesmarta lösningar tillämpas, samt 6 månader efter ombyggnaden då förskolan åter är i drift. I projektet analyserades förekomsten av flyktiga organiska ämnen (VOC) i luft samt förekomsten av semiflyktiga organiska ämnen (SVOC) i luft och damm från förskolans innemiljö samt i tillhörande golvmaterial. De relevanta SVOC-ämnena var ftalater och andra mjukgörare, organofosfater , polycykliska aromatiska kolväten, bisfenoler och polybromerade difenyletrar. Tre luftprover analyserades med avseende på VOC och SVOC och fyra prover vardera av damm och material analyserades med avseende på SVOC.

    Halterna av flyktiga organiska ämnen i förskolans luft var lägre än medianhalten av VOC i en genomsnittlig svensk bostad. Aldehyder och organiska syror var de ämnesgrupper som fanns i högst koncentration i luftproverna. Resultaten visade att ftalater och organofosfater dominerade den kemiska sammansättningen av SVOC i de provmatriserna där de analyserades. De lättmolekylära ämnena i varje ämnesgrupp återfanns i högre halter i luftproverna och de högmolekylära ämnena återfanns i högre halter i dammproverna. Resultaten har jämförts med uppgifter från nationella och internationella publicerade studier. Denna jämförelse visar att halter av kemikalierna som har analyserats i denna studie var i samma storleksordning eller lägre (i vissa fall mycket lägre) än motsvarande halter av respektive ämnen i inomhusluft och damm från andra studier.

    This report is only available in Swedish. English summary is available in the report.

    Download full text (pdf)
    FULLTEXT01
  • 9.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Mercury flux over West Antarctic Seas during winter, spring and summer2017In: Marine Chemistry, ISSN 0304-4203, E-ISSN 1872-7581, no 193, p. 44-54Article in journal (Refereed)
    Abstract [en]

    For the first time elemental mercury in air and surface seawater was measured continuously in the remote seas of western Antarctica. A major contributor to atmospheric emissions of the toxic and globally dispersed pollutant mercury is the re-evasion from water surfaces, due to a supersaturation of dissolved gaseous mercury (DGM) in surface water. In this study the degree of saturation and mercury flux at the air-sea surface interface have been estimated from continuous measurements of gaseous elemental mercury (GEM) or total gaseous mercury (TGM) in air, DGM in surface water and meteorological parameters. The measurements were performed during winter and spring (2013) in the Weddell Sea and during summer (2010/2011) in the Bellingshausen, Amundsen and Ross Seas, and show spatial and seasonal variations.

    The average DGM concentration in surface water in open sea was highest during spring (12 ± 7 pg L− 1) and lowest during summer (7 ± 6.8 pg L− 1), resulting in a net evasion of mercury during spring (1.1 ± 1.6 ng m− 2 h− 1) and a net deposition during summer (− 0.2 ± 1.3 ng m− 2 h− 1). In open sea, higher average concentrations of GEM (or TGM) and DGM were found close to the Drake Passage compared to in the Bellingshausen and Weddell Seas. Emission sources from the South American continent, identified with back trajectories, were suggested to explain the observed variations. The yearly mercury evasion from open sea surfaces in the Southern Ocean was estimated to 30 (− 450–1700) tons, using the average (and min and max) flux rates obtained in this study. Higher DGM was measured under sea ice (19–62 pg L− 1) compared to in open sea due to a capsuling effect, resulting in a theoretical prevented evasion of 520 (0–3400) tons per year. Diminishing sea ice and higher water temperatures in polar regions could result in increased mercury evasion to the atmosphere. However, the contribution of the Southern Ocean to the global modeled annual emissions of mercury from sea surfaces would probably only be a few percent.

  • 10.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    New Biocomposites for Innovative Construction Façades and Interior Partitions2018In: Journal of Facade Design and Engineering, ISSN 2213-302X, no 6, p. 67-85Article in journal (Refereed)
    Abstract [en]

    European Research Project OSIRYS developed a holistic solution for facades and interior partitions ready to be applied in building retrofitting and new construction. The project uses biocomposites as the base material to define different products: a multilayer façade, a curtain wall, a window and an interior partition.

    The biocomposites developed have different functionalities able to meet the strictest requisites of the European Building Codes as regards fire and structural performance, improve indoor air quality by VOC (volatile organic compounds) and microorganism’s elimination, increase thermal insulation and increase durability of the construction elements. The new systems are lighter than the traditional ones leading to weight savings and will reduce implementation costs during both manufacturing and assembly processes due to an industrialized based concept using modular elements.

  • 11.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Perceived indoor air quality and its relationship to air pollutants in French dwellings2017Article in journal (Refereed)
    Abstract [en]

    The perception was assessed on a nine-grade scale by both the occupants of the dwellings and the inspectors who performed the measurements. The occupants perceived the air quality in their homes as more pleasant than the inspectors. The inspectors perceived the air quality as more unpleasant in dwellings in which the residents smoked indoors.

    Significant associations between PIAQ and indoor air pollutant concentrations were observed for both the inspectors and, to a lesser extent, the occupants. Introducing confounding parameters, such as building and personal characteristics, into a multivariate model suppressed most of the observed bivariate correlations and identified the tenure status of the occupants and their occupation as the parameters that most influenced their PIAQ. For the inspectors, perceived air quality was affected by the presence of smokers, the season, the type of ventilation, retrofitting, and the concentrations of acetaldehyde and acrolein.

  • 12.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Seasonal study of mercury species in the Antarctic sea ice2016In: Environmental Science and Technology, ISSN 0013-936X, E-ISSN 1520-5851Article in journal (Refereed)
    Abstract [en]

    Limited studies have been conducted on mercury concentrations in the polar cryosphere and the factors affecting the distribution of mercury within sea ice and snow are poorly understood. Here we present the first comprehensive seasonal study of elemental and total mercury concentrations in the Antarctic sea ice environment covering data from measurements in air, sea ice, seawater, snow, frost flowers, and brine. The average concentration of total mercury in sea ice decreased from winter to spring while the average elemental mercury concentration increased from winter to summer.

    The opposite trends suggest potential photo- or dark oxidation/reduction processes within the ice and an eventual loss of mercury via brine drainage or gas evasion of elemental mercury. Our results indicate a seasonal variation of mercury species in the polar sea ice environment probably due to varying factors such as solar radiation, temperature, brine volume, and atmospheric deposition. This study shows that the sea ice environment is a significant interphase between the polar ocean and the atmosphere and should be accounted for when studying how climate change may affect the mercury cycle in polar regions.

  • 13.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Speciation of mercury in the waters of the Weddell, Amundsen and Ross Seas (Southern Ocean)2017In: Marine Chemistry, ISSN 0304-4203, E-ISSN 1872-7581, no 193, p. 20-33Article in journal (Refereed)
    Abstract [en]

    Despite the distance from large anthropogenic emission sources, toxic mercury is transported via the atmosphere and oceans to the Southern Ocean. Seawater samples were collected at selected stations and were analysed for total mercury (HgT) (8 stations), dissolved gaseous mercury (DGM) (62 stations) and methylmercury (12 stations) during winter (Weddell Sea), spring (Weddell Sea) and summer (Amundsen and Ross Seas) in the Southern Ocean. The HgT distribution in water columns was found to not vary significantly with depth. In the Weddell Sea the average column concentration was higher in spring (2.6 ± 1.3 pM, 2 stations) than in winter (2.0 ± 1.0 pM, 6 stations). We hypothesize that the seasonal HgT increase is due to atmospheric deposition of particulate Hg(II) formed during atmospheric mercury depletion events (AMDEs), as well as the addition of inorganic mercury species from melting sea ice and snow. Furthermore, HgT concentrations found in this study were significantly higher than previously measured in the Southern Ocean (Cossa et al., 2011), which was hypothesized to be due to seasonal variations in atmospheric deposition.

    The average water column DGM concentration in the Weddell Sea was 454 ± 254 fM in winter and 384 ± 239 fM in spring. The lowest average DGM concentration was found in summer in the Amundsen and Ross Seas (299 ± 137 fM). The highest observed concentration in winter was hypothesized to be caused by the larger sea ice coverage, which is known to reduce the evasion of Hg(0) from the sea surface.

    The average monomethylmercury (MMHg) concentration in the Weddell Sea was 60 ± 30 fM in winter (6 stations) and 95 ± 85 fM in spring (2 stations), showing no significant seasonal difference. In the Amundsen and Ross Seas the summer average concentration of MeHg (MMHg and dimethylmercury; DMHg) was 135 ± 189 fM (4 stations). The highest MeHg concentration was found in modified circumpolar deep water, which is known to have high primary production.

  • 14.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Bibi, Momina
    IVL Swedish Environmental Research Institute.
    Egelrud, Liselott
    IVL Swedish Environmental Research Institute.
    Kemikaliesmarta åtgärder i förskola2017Report (Other academic)
    Abstract [en]

    Denna undersökning är en del av en pilotstudie ”Kemikaliesmarta åtgärder i förskola”där kemikaliebelastningen i innemiljön ska kartläggas och bedömas i 1) en förskola före och efter en ombyggnad samt 6 månader efter ombygganden då förskolan åter är i drift; 2) en nybyggd förskola; 3) en förskola före och efter att kemikaliesmarta åtgärder på nivå 1 i enlighet med dokumentet Vägledning för kemikaliesmart förskola har tillämpats.

    Målet med detta delprojekt är att kartlägga förekomsten av hälsofarliga ämnen i en förskola där de kemikaliesmarta åtgärderna ska genomföras. I denna rapport redovisas resultat från det tredje delprojektet för förskolan Korpen i Hägersten/Liljeholmens stadsdelsförvaltning, före genomförande av de kemikaliesmarta åtgärderna.

    Här rapporterar vi förekomsten av flyktiga organiska ämnen (VOC Volatile Organic Compounds, totalhalt uttryckt som TVOC Total VOC) i luft samt förekomsten av semiflyktiga organiska ämnen (SVOC Semivolatile Organic Compounds) i luft och damm från förskolans innemiljö samt i tillhörande materialprover från golv, mattor/halkskydd och vilomadrass. De relevanta SVOC-ämnena var ftalater och alternativa mjukgörare, organofosfater, polycykliska aromatiska kolväten (PAH), bisfenoler samt bromerade flamskyddsmedel (BFR), bl.a. polybromerade difenyletrar (PBDE) . Tre luftprover analyserades med avseende på VOC och SVOC och tre dammprov och sex materialprov (PVC-golv, halkskydd under en samlingsmatta, överdrag på och skumgummi från en vilomadrass) analyserades med avseende på SVOC.

    TVOC i förskolans luft var jämförbara med medianhalten av TVOC i en genomsnittlig svensk bostad. Aldehyder och alkoholer var de ämnesgrupper som fanns i högst halter i luftproverna. Mätresultaten visade att organofosfater, PAH:er samt ftalater och alternativa mjukgörare var de SVOC-ämnesgrupper som förekom i högst halter i luftprover. Ftalater och alternativa mjukgörare var den SVOC-ämnesgrupp som dominerade sammansättningen i damm och material, följda av organofosfater. De lågmolekylära ämnena i varje ämnesgrupp återfanns i högre halter i luftproverna och de högmolekylära ämnena återfanns i högre halter i dammproverna.

    Mätresultaten från denna studie har jämförts med andra nationella och internationella studier i förskolemiljö. Jämförelsen visar att halterna i denna studie var i samma storleksordning som, eller lägre än, motsvarande halter av respektive ämnen i inomhusluft och damm från andra studier med undantag för halterna av ftalaten DiNP samt bromerade flamskyddsmedel (BFR) i damm som var högre än tidigare publicerade resultat. Jämförelse med en färsk svensk studie av halter och beräknad exponering för farliga kemikalier i damm från 100 förskolor visar att barn i denna förskola exponeras på ungefär samma låga nivå som barn från de andra förskolorna.

    Resultaten indikerar att förbudet mot det bromerade flamskyddsmedlet PBDE har haft effekt, med lägre halter i förskolan, medan förbuden mot andra flamskyddsmedel, HBCD och BDE 209, ännu inte givit effekt. Resultaten för nya flamskyddsmedel, EBFR indikerar att vissa av dessa BFR används som ersättare för de förbjudna ämnena.

    Det bör noteras att några förbjudna bromerade flamskyddsmedel har påträffats i högre halter än förväntat i de utrymmen som undersöktes. I denna förskola ska kemikaliesmarta åtgärder för att minska förekomsten av farliga kemikalier i barnens miljö genomföras. Det är motiverat att undersöka möjliga källor till dessa BRF, innan kemikaliesmarta åtgärder vidtas.

    Download full text (pdf)
    FULLTEXT01
  • 15.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Bibi, Momina
    IVL Swedish Environmental Research Institute.
    Egelrud, Liselott
    IVL Swedish Environmental Research Institute.
    Kemikaliesmarta åtgärder i förskola2017Report (Other academic)
    Abstract [en]

    Denna undersökning är en del av en pilotstudie ”Kemikaliesmarta åtgärder i förskola”där kemikaliebelastningen i innemiljön ska kartläggas och bedömas i 1) en förskola före och efter en ombyggnad samt 6 månader efter ombygganden då förskolan åter är i drift; 2) en nybyggd förskola; 3) en förskola före och efter att kemikaliesmarta åtgärder på nivå 1 i enlighet med dokumentet Vägledning för kemikaliesmart förskola har tillämpats.

    Målet med detta delprojekt är att kartlägga förekomsten av hälsofarliga ämnen i en nybyggd förskola som tillämpat SISABs vägledning för kemikaliesmart förskola genom miljöstyrningsrutiner som innefattade kemikaliekrav på byggprodukter. I denna rapport redovisas resultat från delprojektet för den nybyggda förskolan Hovet i Stockholm, Hägersten/Liljeholmens stadsdelsförvaltning.

    Här rapporterar vi förekomsten av flyktiga organiska ämnen (VOC Volatile Organic Compounds) i luft samt förekomsten av semiflyktiga organiska ämnen (SVOC Semivolatile Organic Compounds) i luft och damm från förskolans innemiljö samt i tillhörande materialprover från golv, matta och vilomadrass. De relevanta SVOC-ämnena var ftalater och alternativa mjukgörare, organofosfater, polycykliska aromatiska kolväten (PAH), bisfenoler samt polybromerade difenyletrar (PBDE) och andra bromerade flamskyddsmedel. Tre luftprover analyserades med avseende på VOC och SVOC och tre prover vardera av damm och material (halkskydd under en samlingsmatta, överdrag på en vilomadrass och PVC-golv) analyserades med avseende på SVOC.

    Totalhalterna av flyktiga organiska ämnen (TVOC) i förskolans luft var jämförbara med medianhalten av TVOC i en genomsnittlig svensk bostad. Aldehyder, alkoholer och organiska syror var de ämnesgrupper som fanns i högst koncentration i luftproverna. Mätresultaten visade att ftalater och organofosfater var de SVOC som förekom i högst halter i prov från luft, damm och material. De lågmolekylära ämnena i varje ämnesgrupp återfanns i högre halter i luftproverna och de högmolekylära ämnena återfanns i högre halter i dammproverna.

    Mätresultaten från denna studie har jämförts med andra nationella och internationella studier i förskolemiljö. Jämförelsen visar att halterna i denna studie var i samma storleksordning som, eller lägre (i vissa fall mycket lägre) än, motsvarande halter av respektive ämnen i inomhusluft och damm från andra studier. Jämförelsen med en färsk svensk studie av halter och beräknad exponering för farliga kemikalier i damm från 100 förskolor visar att barn i denna förskolan löper ytterligare lägre risk för exponeringen än de redan väldigt låga riskeran i de andra förskolorna.

    En viktig slutsats är att de tillståndspliktiga (konstaterat farliga) ftalaterna samt PBDE och HBCD som har förbjudits eller reglerats, finns i ytterst låga halter i denna förskola, vilket visar att SISAB:s arbete med att ställa miljökrav med avseende på farliga kemikalier har gett effekt.

    Download full text (pdf)
    FULLTEXT01
  • 16.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute Göteborg Sweden.
    de Wit, Cynthia A.
    Department of Environmental Science Stockholm University Stockholm Sweden.
    Giovanoulis, Georgios
    IVL Swedish Environmental Research Institute Stockholm Sweden.
    Fäldt, Jenny
    City of Stockholm Environment and Health Administration Environmental Analysis Stockholm Sweden.
    Karlson, Linnéa
    City of Stockholm Environment and Health Administration Environmental Analysis Stockholm Sweden.
    The effect of reduction measures on concentrations of hazardous semivolatile organic compounds in indoor air and dust of Swedish preschools2021In: Indoor Air, ISSN 0905-6947, E-ISSN 1600-0668Article in journal (Refereed)
    Abstract [en]

    Young children spend a substantial part of their waking time in preschools. It is therefore important to reduce the load of hazardous semivolatile organic compounds (SVOCs) in the preschools’ indoor environment. The presence and levels of five SVOC groups were evaluated (1) in a newly built preschool, (2) before and after renovation of a preschool, and (3) in a preschool where SVOC-containing articles were removed. The new building and therenovation were performed using construction materials that were approved with respect to content of restricted chemicals. SVOC substance groups were measured in indoor air and settled dust and included phthalates and alternative plasticizers, organophosphate esters (OPEs), brominated flame retardants, and bisphenols.

    The most abundant substance groups in both indoor air and dust were phthalates and alternative plasticizers and OPEs. SVOC concentrations were lower or of the same order of magnitude as those reported in comparable studies. The relative Cumulative Hazard Quotient (HQcum) was used to assess the effects of the different reduction measures on children's SVOC exposure from indoor air and dust in the preschools. HQcum values were low (1.0–6.1%)in all three preschools and decreased further after renovation and article substitution. The SVOCs concentrationsdecreased significantly more in the preschool renovated with the approved building materials than in the preschool where the SVOC-containing articles were removed.

  • 17.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Fridén, Håkan
    IVL Swedish Environmental Research Institute.
    Riskbedömning av svenska sjömäns yrkesmässiga exponering för toxiska luftföroreningar2018Report (Other academic)
    Abstract [en]

    Ett fartyg utgör både en arbetsmiljö och en boendemiljö och besättningen vistas ofta långa tider ombord. Ombordtjänstgöringen kan vara i veckor eller månader och kan ibland passera flera klimatzoner. Eftersom vi tillbringar den största delen av vår tid inomhus är det där vi främst exponeras. På ett fartyg kan det vara svårt att påverka sin exponering för kemiska ämnen eftersom möjligheten att byta miljö är liten. Det är därför extra viktigt att innemiljön är god.

    Luften ombord präglas till stor del av de kemiska ämnen som har sitt ursprung i fartygets bränsle, smörjoljor och motoravgaser. Det är en komplicerad blandning som innehåller mest koldioxid, kolmonoxid, svaveldioxid, kväveoxider men också kolväten såsom bensen, toluen, xylener, och polycykliska aromatiska kolväten. Flera av dessa ämnen är cancerframkallande eller hälsoskadliga på annat sätt. Det finns dock få vetenskapliga studier som undersökt den personliga exponeringen för farliga luftföroreningar som de sjömän som arbetar ombord utsätts för.

    Syftet med projektet som presenteras i denna rapport var att kartlägga den personliga exponeringen för de toxiska luftföroreningarna bensen, kvävedioxid (NO2) och polycykliska aromatiska kolväten (PAH) som alla kan spåras till fartygsbränslet och bränsleavgaser. Den uppmätta exponeringen har analyserats för att kunna identifiera eventuella skillnader mellan typ av fartyg och mellan olika avdelningar och befattningar ombord. De uppmätta halterna har jämförts med svenska lagkrav men också med internationella, icke bindande riktlinjer för innemiljöer, för att få en uppfattning om halternas storlek. Dessutom har vi undersökt hur besättningen själva upplever sin luftkvalitet ombord. Projektets övergripande mål var att utveckla en metod för riskbedömning av exponeringen som kan användas av branschen, samt att formulera praktiska råd och rekommendationer.

    Download full text (pdf)
    FULLTEXT01
  • 18.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Fridén, Håkan
    IVL Swedish Environmental Research Institute.
    Giovanoulis, Georgios
    IVL Swedish Environmental Research Institute.
    Thorsén, Gunnar
    IVL Swedish Environmental Research Institute.
    Kemikaliesmart förskola - Kemikaliebelastning i tre förskolors innemiljö2020Report (Other academic)
    Abstract [sv]

    Projektet ”Kemikaliesmarta åtgärder i förskola” har kartlagt och bedömt förändring i förekomsten av farliga kemikalier i förskolemiljö. Tre kemikaliesmarta tillvägagångssätt har tillämpats: nybyggnation enligt fastighetsägarens miljöstyrningsrutiner som bland annat innefattar val av byggmaterial som är godkända enlig Byggvarubedömningen, ombyggnation med tillämpning av samma rutiner samt genomförandet av kemikaliesmarta åtgärder på nivå 1 i enlighet med dokumentet Vägledning för kemikaliesmart förskola som innebär utfasning av föremål som misstänkt innehålla de farliga kemikalierna från förskolan innemiljö.

    Download full text (pdf)
    FULLTEXT01
  • 19.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Hallgren, Karin
    IVL Swedish Environmental Research Institute.
    Öberg, Vera
    IVL Swedish Environmental Research Institute.
    Innemiljö i HSB Living Lab – En studie av innemiljön under en fastighets första år B2018Report (Other academic)
    Abstract [sv]

    Människor tillbringar huvuddelen, upp till 90 %, av sina liv inomhus. Därför har inomhusmiljön stor betydelse för människors hälsa. Till det svenska miljömålet ”God bebyggd miljö” finns en indikator som handlar om hur stor andel av den vuxna befolkningen som upplever besvär av inomhusmiljön. HSB Living Lab är en fastighet som byggts för att fungera både som student- och forskarbostäder och som ett levande laboratorium för test och utvärdering av bland annat innemiljö men även olika byggnadstekniska lösningar mm.

    Under fastighetens första år, har en studie gjorts av innemiljön. Resultatet redovisas i denna rapport. Undersökningen har omfattat uppmätt och upplevd luftkvalitet inomhus under mer än ett år i två lägenheter i HSB Living Lab. Målet med projektet var att följa upp och dokumentera luftkvaliteten och att bedöma påverkan av byggnaden, inredningen och mänskliga aktiviteterna på den.

    Mätningarna har utförts i ett oinrett och oventilerat rum med rester av byggmaterial och ouppackade möbler, i ett gemensamt utrymme med köksinredning, i ett studentrum och i en bebodd trerumslägenhet. I mätningarna ingick parametrar för inneklimat som temperatur och relativ luftfuktighet, halter av gasformiga luftföroreningar koldioxid, kvävedioxid, ozon, flyktiga organiska ämnen och formaldehyd samt partikelhalter PM10 och PM2.5. Dessutom undersöktes upplevd luftkvalitet och termisk komfort med en enkät.

    Resultaten av mätningarna jämfördes med rekommenderade riktvärden för god luftkvalitet inomhus. Med undantag för det oinredda och oventilerade rummet var luftkvaliteten bra och halterna under de rekommenderade riktvärdena. Den upplevda luftkvaliteten var betydligt bättre i de möblerade, bebodda och ventilerade bostäderna än i det oinredda rummet.

    När ventilationen startades efter avslutade byggarbeten, hade det en positiv inverkan på luftkvalitet i byggnaden, vilket är vad som kan förväntas. Andra parametrar som påverkade innemiljö var mänskliga aktiviteter som vädring/öppnade fönster som påverkade temperaturen och matlagning som påverkade partikelhalten.

    Download full text (pdf)
    FULLTEXT01
  • 20.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Sahlberg, Bo
    IVL Swedish Environmental Research Institute.
    Duis, Willem
    IVL Swedish Environmental Research Institute.
    God innemiljö i energieffektiva byggnader2017Report (Other academic)
    Abstract [en]

    Människor tillbringar i genomsnitt 85-95 % av sin tid i olika innemiljöer. Det är bevisat att god luftkvalitet inomhus främjar mentala, kognitiva och kreativa funktioner. Energieffektiva hus byggs mycket lufttäta, varför ventilationssystemet, emission av kemiska ämnen från byggmaterial och mänskliga aktiviteter har en avgörande betydelse för luftkvaliteten inomhus. Det är av största vikt att energieffektivisering av byggnader görs utan att äventyra en god innemiljö eftersom problem kopplade till innemiljön kan leda till ohälsa.

    Denna pilotstudien syftade till att ge underlag till utveckling av ett diagnostiskt verktyg för helhetsbed ömning av innemiljö i bostäder. Fastigheten tillhör fastighetsägare AB Stockholmshem. Arbetet genomfördes under tiden 2017-02-23 – 2017-04-03 och innefattade mätningar och en enkäterundersökning om upplevelsen av luftkvalitet inomhus. Undersökningen bestod av mätning av halter av luftföroreningarna kvävedioxid, ozon, totalhalt av flyktiga organiska ämnen (TVOC), formaldehyd och koncentrationer av partiklar PM10 och PM2.5 i inomhusluft. De gasformiga luftföroreningarna mättes med diffusiva provtagare och partiklarna med en direktivisande optisk partikelräknare under en vecka. Samtidigt registrerades temperatur, relativ luftfuktighet och halten av koldioxid. Den upplevda luftkvaliteten studerades genom enkäter där både de boende och inspektör som installerade mätutrustningen besvarade frågor om allmän acceptans av luftkvalitet, lukt och upplevelse av fuktighet och termisk komfort.

    Temperaturen i alla lägenheterna var mycket stabil och låg kring 22 oC. Relativa luftfuktigheten var låg med medelvärde på 21 %. Luftflöden låg med ett undantag över Boverkets minimikrav på 0,35 Liter/s, m2. Halten av koldioxid har inte överskridit det rekommenderade värdet på 1 000 ppm under längre tidsperioder. De uppmätta halterna av luftföroreningar var med några få undantag under de rekommendera riktvärdena för god luftkvalitet inomhus.

    Halterna av de individuella luftföroreningarna och parametrarna för termisk komfort har använts för beräkningen av ett Indoor Environmental Index (IEI) för varje lägenhet. Indexet förenklar tolkningen av de uppmätta parametrarna och möjliggör en rankning av innemiljö mellan bostäder (och byggnader). Värden av IEI hamnade i intervallet 4 – 6 på en skala mellan 0 (bäst) och 10 (sämst). Det fanns ingen skillnad i upplevelse av innemiljö mellan hyresgästerna och inspektören förutom för upplevelsen av luftens fuktighet (Wilcoxon matched-pairs signed-rank test). Boenden uppfattade luften i sina lägenheter som torrare än inspektören. Regressionsberäkningar visade svaga och inte signifikanta korrelationer mellan mätningar och upplevd luftkvalitet.

    Resultaten visar att god ventilation och halten av koldioxid som den enda indikator för luftkvalitet inte alltid garanterar att halterna av individuella luftföroreningar är under riktvärden för god luftkvalitet inomhus. Enkätundersökningar om upplevd innemiljö kan inte ersätta faktiska mätningar. Bostäderna i denna studie var ganska få och homogena med avseende på energianvändning och byggmaterial. För att kunna analysera samband mellan bostad och luftkvalitet borde man beakta olika byggnadstekniska lösningar, ålder, geografiskt läge, ventilations- och uppvärmningssätt, inredning och de boendes aktivitetsmönster och beteende. Detta kräver dock mätdata från ett betydligt större antal olika bostäder.

    Download full text (pdf)
    FULLTEXT01
  • 21.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Salvador, C.M.
    Bekö, G.
    Weschler, C.J.
    Morrison, G.
    Le Breton, M.
    Hallquist, M.
    Ekberg, L.
    Indoor ozone/human chemistry and ventilation strategies.2019In: Indoor Air, ISSN 0905-6947, E-ISSN 1600-0668, no 29, p. 913–925-Article in journal (Refereed)
  • 22.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Strandberg, Bo
    Österman, Cecilia
    IVL Swedish Environmental Research Institute.
    Koca Akdeva, Hatice
    Moldanova, Jana
    IVL Swedish Environmental Research Institute.
    The Use of Polyurethane Foam (PUF) Passive Air Samplers in Exposure Studies to PAHs in Swedish Seafarers2020In: Polycyclic aromatic compounds (Print), ISSN 1040-6638, E-ISSN 1563-5333Article in journal (Refereed)
    Abstract [en]

    The aim of this study was to test the usefulness of polyurethane foam (PUF) passive air samplers as stationary, and, for the first time, as personal samplers for one week’s sampling period of polycyclic aromatic hydrocarbons (PAHs) in occupational air. Routine monitoring of workplace exposure is commonly performed with active sampling. However, active samplers can sometimes be unsuitable; e.g., it is difficult to make time-integrated measurements, longer than one day, and they can be noisy and obstructive. Indoor air quality on ships is an important aspect of the environment which has not been studied extensively on ships. For seafarers, good indoor air quality becomes particularly important as the ship represents both a working and living environment. In this study, measurements were carried out on two occasions on two different ships, at different workplaces, and for various personnel categories. On each ship, measurements were performed before and after a change of the type of fuel that the ships were operating on. We found a considerable wide range of PAHs exposure levels for the various workplaces and personnel categories on the ships. The stationary measurements, sum 32 PAHs, ranged from 33- 39,000 ng m 3 and the personal exposure measurements ranged from 61- 8,400 ng m 3. The results point to that the content of PAHs in the fuel can affect the indoor air environment on the entire ship. Further, the results demonstrate that the PUF sampler can serve as a simple and usable screening tool for estimating and tracking point sources of PAHs in microenvironments. Moreover, this study contributes to increased knowledge of exposure to and sources of PAHs for seafarers.

  • 23.
    Langer, Sarka
    et al.
    IVL Swedish Environmental Research Institute.
    Österman, Cecilia
    IVL Swedish Environmental Research Institute.
    Moldanova, Jana
    IVL Swedish Environmental Research Institute.
    Fridén, Håkan
    IVL Swedish Environmental Research Institute.
    Strandberg, Bo
    Impacts of fuel quality on indoor environment onboard a ship: From policy to practice2020In: Transportation Research Part D: Transport and Environment, ISSN 1361-9209, E-ISSN 1879-2340, no 83, article id 102352Article in journal (Refereed)
    Abstract [en]

    Environmental considerations, concerning the negative impacts of ship exhaust gases and particles on ambient air quality, are behind the requirements of cleaner marine fuels currently applied in designated emission control areas (ECAs). We investigated the impact of a ship operating on two types of fuel on the indoor air quality onboard. Gaseous and particulate air pollutants were measured in the engine room and the accommodation sections on-board an icebreaker operating first on Heavy Fuel Oil (HFO, 1%-S), and later Marine Diesel Oil (MDO, 0.1%-S). Statistically significant decrease of SO2, NOx, PM2.5 and particle number concentration were observed when the ship was operating on MDO. Due to the higher content of alkylated PAHs in MDO compared to HFO, the concentration of PAHs increased during operation on MDO. The particulate PAHs classified as carcinogens, were similar to or lower in the MDO campaign. Chemical analysis of PM2.5 revealed that the particles consisted mainly of organic carbon and sulfate, although the fraction of metals was quite large in particles from the engine room. Principal Component Analysis of all measured parameters showed a clear difference between HFO and MDO fuel on the indoor environmental quality on-board the ship. This empirical study poses a first example on how environmental policy-making impacts not only the primary target at a global level, but also brings unexpected localized benefits at workplace level. The study emphasizes the need of further investigations on the impact of new marine fuels and technologies on the indoor air environments on board.

  • 24. Licina, Dusan
    et al.
    Langer, Sarka
    Indoor air quality investigation before and after relocation to WELL-certified office buildings2021In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 204, p. 108182-108182, article id 108182Article in journal (Refereed)
    Abstract [en]

    Air pollutant exposure in workplace environments has been associated with health and cognitive outcomes ofworkers. While green building certification programs have been instrumental in promoting indoor air quality(IAQ), the present literature indicates inconsistent evidence. Recent emergence and proliferation of WELL certification program that prioritizes human health has evoked new questions about its effectiveness in relation toIAQ. To investigate the effectiveness of the WELL certification, we have quantitatively compared IAQ resultsbefore and after relocation to two WELL-certified office buildings using the same cohort of occupants.

    Physicalmeasures included integrated samples of TVOC, individual VOC, formaldehyde and acetaldehyde, NO2, SO2, O3and longitudinal records of CO2 and size-resolved particles. Complementary survey responses about satisfactionwith IAQ and thermal comfort were collected from ~250 employees. For the majority of air pollutants, there wasno significant concentration difference between non-WELL and WELL buildings, but not always. The WELL-certified buildings had substantially higher levels of TVOC and individual VOC associated with paints, especiallyshortly after the relocation. However, there was statistically significant improvement in IAQ satisfactionafter relocation into WELL buildings regardless of the air pollution levels, possibly confounded by thermalenvironment, awareness of the WELL certification or other non-measurable factors.

  • 25.
    Moldanova, Jana
    et al.
    IVL Swedish Environmental Research Institute.
    Parsmo, Rasmus
    IVL Swedish Environmental Research Institute.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Salberg, Håkan
    IVL Swedish Environmental Research Institute.
    Jutterström, Sara
    IVL Swedish Environmental Research Institute.
    Rydström, Anne-Marie
    IVL Swedish Environmental Research Institute.
    Improving cabin air quality in road vehicles - Vägar till förbättrad luftkvalitet i fordon2019Report (Other academic)
    Abstract [en]

    The most important parameters that influence the air quality in vehicles are the choice of cabin air filter and the air quality outside the vehicle. Real-life driving test methods for measurement in traffic environments developed in AQIFOR project showed repeatable differences between the reduction efficiency of the various cabin air filters in the car ventilation systems. Additional parameters that affected the reduction efficiency for air pollutants in the vehicle were ventilation speed and degree of air recirculation in the ventilation. Different air pollutants are affected differently. All filters tested purified air from particles; the reduction efficiency for PM2.5 was from 40% to over 80% for different filters, particles in the size range 10 - 600 nm were more difficult to clean than larger particles. Filters containing active carbon also purified the air from NO2; reduction efficiency showed similar pattern to reduction efficiency for particles. Sampling for VOC and PAH showed that volatiles are not purified by filters, but the less volatile species are effectively reduced. The project also investigated occupational exposure of professional drivers to air pollution in both passenger cars and trucks. The results showed that the drivers' exposure to benzo (a) pyrene, 1,3-butadiene and benzene was low, well below the working environment limit values.

    Download full text (pdf)
    FULLTEXT01
  • 26. Psomas, Theofanis
    et al.
    Teli, Despoina
    Langer, Sarka
    Wahlgren, Paula
    Wargocki, Pawel
    Indoor humidity of dwellings and association with building characteristics, behaviors and health in a northern climate2021In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 198, p. 107885-107885, article id 107885Article in journal (Refereed)
    Abstract [en]

    Data from a nationwide survey on the status of the Swedish residential building stock and indoor air quality wasplaced in the public domain by the National Board of Housing, Building and Planning of Sweden. The currentresearch investigates the indoor humidity conditions in Swedish residential buildings, single-family houses andapartments, assessing the measurements from the extensive BETSI-survey against adjusted relative humiditylevels based on existing norms and Standards. The aim of this study is to investigate associations and correlationsbetween relative humidity levels and multiple building and system characteristics, occupancy patterns and behaviors and health symptoms-complaints. The analysis uses 13 categorical and 9 continuous variables-parameters of the examined dwellings.Analysis shows that low indoor relative humidity is a realistic issue in Swedish dwellings during the heatingseason. The issue is more prevalent in apartments than single-family houses. In addition, low indoor relativehumidity seems to be more extensive in dwellings with higher indoor temperature, smaller volume, higherventilation rate and frequent airing practices, lower number of occupants, constructed mainly after 1985, in citysuburbs and in the northern parts of the country. The developed multinomial logistic regression model maypredict very accurately the relative humidity level of the Swedish dwellings, during heating season. This analysisoffers additional evidence to the scientific literature for possible correlation of low relative humidity with specifichealth symptoms, complaints and disturbances.

  • 27. Teli, Despoina
    et al.
    Psomas, Theofanis
    Langer, Sarka
    Trüschel, Anders
    Dalenbäck, Jan-Olof
    Drivers of winter indoor temperatures in Swedish dwellings: Investigating the tails of the distribution2021In: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 202, p. 108018-108018, article id 108018Article in journal (Refereed)
    Abstract [en]

    Residential indoor climate is a key factor for occupant comfort, health and wellbeing, while also affecting the buildings’ energy demand. A strong focus has been traditionally placed on low winter indoor temperatures in dwellings due to their considerable health impacts. However, there is a trend towards high and stable indoor temperatures, which also have significant implications. This paper investigates the drivers of winter indoor temperatures by analysing the following three metrics of measured temperatures in a sample of 1039 Swedish dwellings: a) level, through the sample dwellings’ standardised indoor temperatures at 5oC outdoor temperature, b) daily variation, through the standard deviation of the indoor temperature and c) shape, using daily indoor temperature profiles derived from cluster analysis. The study explores the association of these metrics to building-, dwelling- and occupant-related parameters.

    The analysis shows that 80% of the standardised indoor temperatures were above 21oC, with one third of the latter being above 23oC, while 82% of dwellings had constant temperatures throughout the day. High winter indoor temperatures were more evident in middle-placed apartments in multi-family buildings connected to district heating and in better insulated single-family houses. High temperatures were also associated with experiencing draft from windows, too warm conditions in winter and difficulty to control the indoor temperature, but not with the overall thermal comfort assessment which was very positive in both the high and low temperature tails. Long-term adaptation effects, established norms and comfort expectations are discussed as important confounding factors in the development of residential indoor temperatures.

  • 28.
    Yang, Shen
    et al.
    Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne 1015, Switzerland.
    Licina, Dusan
    Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne 1015, Switzerland.
    Weschler, Charles J.
    International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Kongens Lyngby 2800, Denmark;Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States.
    Wang, Nijing
    Max Planck Institute for Chemistry, Hahn-Meitner Weg 1, Mainz 55128, Germany.
    Zannoni, Nora
    Max Planck Institute for Chemistry, Hahn-Meitner Weg 1, Mainz 55128, Germany.
    Li, Mengze
    Max Planck Institute for Chemistry, Hahn-Meitner Weg 1, Mainz 55128, Germany.
    Vanhanen, Joonas
    Airmodus Limited, Erik Palménin Aukio 1, Helsinki FI-00560, Finland.
    Langer, Sarka
    IVL Swedish Environmental Research Institute, Göteborg SE-400 14, Sweden;Department of Architecture and Civil Engineering, Division of Building Services Engineering, Chalmers University of Technology, Göteborg SE-412 96, Sweden.
    Wargocki, Pawel
    International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Kongens Lyngby 2800, Denmark.
    Williams, Jonathan
    Max Planck Institute for Chemistry, Hahn-Meitner Weg 1, Mainz 55128, Germany;Energy, Environment and Water Research Center, The Cyprus Institute, Nicosia 2121, Cyprus.
    Bekö, Gabriel
    International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Kongens Lyngby 2800, Denmark.
    Ozone Initiates Human-Derived Emission of Nanocluster Aerosols2021In: Environmental Science and Technology, ISSN 0013-936X, E-ISSN 1520-5851, Vol. 55, no 21, p. 14536-14545Article in journal (Refereed)
    Abstract [en]

    Nanocluster aerosols (NCAs, particles <3 nm) are important players in drivingclimate feedbacks and processes that impact human health. This study reports, for the first time, NCA formation when gas-phase ozone reacts with human surfaces. In an occupied climatecontrolledchamber, we detected NCA only when ozone was present.

    NCA emissions weredependent on clothing coverage, occupant age, air temperature, and humidity. Ozone-initiated chemistry with human skin lipids (particularly their primary surface reaction products) is thekey mechanism driving NCA emissions, as evidenced by positive correlations with squalene in human skin wipe samples and known gaseous products from ozonolysis of skin lipids. Oxidation by OH radicals, autoxidation reactions, and human-emitted NH3 may also play a role in NCA formation. Such chemical processesare anticipated to generate aerosols of the smallest size (1.18−1.55 nm), whereas larger clusters result from subsequent growth of the smaller aerosols. This study shows that whenever we encounter ozone indoors, where we spend most of our lives, NCAs will be produced in the air around us.

  • 29.
    Zannoni, Nora
    et al.
    Atmospheric Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany.
    Li, Mengze
    Atmospheric Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany.
    Wang, Nijing
    Atmospheric Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany.
    Ernle, Lisa
    Atmospheric Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany.
    Bekö, Gabriel
    International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, 2800 Lyngby, Denmark.
    Wargocki, Pawel
    International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, 2800 Lyngby, Denmark.
    Langer, Sarka
    IVL Swedish Environmental Research Institute, 41133 Göteborg, Sweden;Division of Building Services Engineering, Department of Architecture and Civil Engineering, Chalmers University of Technology, 41296 Göteborg, Sweden.
    Weschler, Charles J.
    International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, 2800 Lyngby, Denmark;Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, New Jersey 08854, United States.
    Morrison, Glenn
    Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, The University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-7431, United States.
    Williams, Jonathan
    Atmospheric Chemistry Department, Max Planck Institute for Chemistry, 55128 Mainz, Germany.
    Effect of Ozone, Clothing, Temperature, and Humidity on the Total OH Reactivity Emitted from Humans2021In: Environmental Science and Technology, ISSN 0013-936X, E-ISSN 1520-5851, Vol. 55, no 20, p. 13614-13624Article in journal (Refereed)
    Abstract [en]

    People influence indoor air chemistry through theirchemical emissions via breath and skin. Previous studies showed thatdirect measurement of total OH reactivity of human emissionsmatched that calculated from parallel measurements of volatile organiccompounds (VOCs) from breath, skin, and the whole body.

    In thisstudy, we determined, with direct measurements from twoindependent groups of four adult volunteers, the effect of indoortemperature and humidity, clothing coverage (amount of exposedskin), and indoor ozone concentration on the total OH reactivity ofgaseous human emissions.

    The results show that the measuredconcentrations of VOCs and ammonia adequately account for themeasured total OH reactivity. The total OH reactivity of humanemissions was primarily affected by ozone reactions with organic skinoilconstituents and increased with exposed skin surface, higher temperature, and higher humidity. Humans emitted a comparabletotal mixing ratio of VOCs and ammonia at elevated temperature-low humidity and elevated temperature-high humidity, withrelatively low diversity in chemical classes.

    In contrast, the total OH reactivity increased with higher temperature and higherhumidity, with a larger diversity in chemical classes compared to the total mixing ratio. Ozone present, carbonyl compounds were thedominant reactive compounds in all of the reported conditions.

  • 30.
    Österman, Cecilia
    et al.
    IVL Swedish Environmental Research Institute.
    Langer, Sarka
    IVL Swedish Environmental Research Institute.
    Moldanova, Jana
    IVL Swedish Environmental Research Institute.
    God innemiljö på svenska fartyg2015Report (Other academic)
    Abstract [sv]

    Miljön ombord på fartyg är viktig för besättningens välbefinnande hälsa och arbetseffektivitet. Inomhusluftens kvalitet och termisk komfort är viktiga delar av innemiljön som inte har studerats så mycket på fartyg. Vid långa resor som varar veckor eller månader och kan passera flera klimatzoner finns inget sätt att byta miljö och ingen utväg från fartyget, och då blir god innemiljön extra viktig eftersom den utgör både arbetsmiljö och boendemiljö (innemiljö). Syftet med denna studie var att kartlägga hur innemiljön på svenska fartyg ser ut, föreslå en enkel övervakningsmetodik för innemiljö samt föreslå förbättringsåtgärder där det behövs. This report is only available in Swedish. You can find an English summary in the report.

    Download full text (pdf)
    FULLTEXT01
1 - 30 of 30
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf