Routine Analysis of Mercury. A comparative Study between two Methods; neutron activation and flameless atomic absorption
Show others and affiliations
1984 (English)Report (Other academic)
Abstract [sv]

Mercury analysis was performed on purely routine basis om samples of organic origin. The object was to compare the two analytical methods at IVL, neutron activation and flaemless atomic absorption, both available as a routine service. The investigation was based on eight samples, run a striplets, showed: Neutron activation has an excellent accuracy with a coefficient of variation of less than 5 % when mercury level exceeds 2 ppb (ng/g). All of the performed analyses gave good results. - Flameless atomic adsorption samples were digested in either of three media: aqua regia (inorganic matter), sulfuric, nitric an dperchloric acid or dulfuric and nitric acids combined with permangante and persulfate. Two performance with aqua regia was acceptable while no agreement was obtianed with the two other methods Loss of mercury occured compared to the reference values. Digestion with permanganate and persulfate showed the best agreement. The maximun loss was 35 %. Moreover detection limit was high because of the high background. At best is was found to be 5 ppb (ng/g). The comparative study gives neutron activation a very strong hand.

Abstract [en]

Mercury analysis was performed on purely routine basis om samples of organic origin. The object was to compare the two analytical methods at IVL, neutron activation and flaemless atomic absorption, both available as a routine service. The investigation was based on eight samples, run a striplets, showed: Neutron activation has an excellent accuracy with a coefficient of variation of less than 5 % when mercury level exceeds 2 ppb (ng/g). All of the performed analyses gave good results. - Flameless atomic adsorption samples were digested in either of three media: aqua regia (inorganic matter), sulfuric, nitric an dperchloric acid or dulfuric and nitric acids combined with permangante and persulfate. Two performance with aqua regia was acceptable while no agreement was obtianed with the two other methods Loss of mercury occured compared to the reference values. Digestion with permanganate and persulfate showed the best agreement. The maximun loss was 35 %. Moreover detection limit was high because of the high background. At best is was found to be 5 ppb (ng/g). The comparative study gives neutron activation a very strong hand.

Place, publisher, year, edition, pages
IVL Svenska Miljöinstitutet, 1984.
Series
B report ; B758
Keywords [sv]
mercury, analysis, neutron activation, atomic absorption
Identifiers
URN: urn:nbn:se:ivl:diva-1416OAI: oai:DiVA.org:ivl-1416DiVA, id: diva2:1550849
Available from: 2021-05-05 Created: 2021-05-05 Last updated: 2025-09-04Bibliographically approved

Open Access in DiVA

fulltext(11572 kB)174 downloads
File information
File name FULLTEXT01.pdfFile size 11572 kBChecksum SHA-512
84c9131c8b104b1446d8522c24e9968185c9922c1756d36a4c34e1f7f96ede77a63f0ab830ed3da4c1a1af50c45251ed45adb9ff31074534cb9057e8b92f4b67
Type fulltextMimetype application/pdf

Search outside of DiVA

GoogleGoogle Scholar
Total: 175 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 85 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf